Test/IT/Medical/Lab Equipment
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JK
- IOa, PLp, DI, IIa 1 active current output HART, 1 passive pulse or status output, 1 active current input, 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JJ
- IOa, PLp, PLp, IIa 1 active current output HART 2 passive pulse output or status output, 1 active current input
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JH
- IOa, PLp, IOp, IIa 1 active current output HART 1 passive pulse or status out, 1 active current input, 1 passive current out
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JG
- IOa, PLp, DI, PLa 1 active current out HART, 1 passive pulse or status out, 1 active pulse or status out, 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JF
- IOa, PLp, DI, PLa pull-up 1 active current out HART, 1 passive pulse or statusout,1active pull-up pulse or statusout,1voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JE
- IOa, PLp, DI, PLp 1 active current output HART 2 passive pulse output or status output 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JD
- IOa, PLp,STp, PLp 1 active current output HART 2 passive pulse output or status output 1 passive status output
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JC
- IOa, PLp, DI, IOa 2 active current output HART 1 passive pulse output or status output 1 voltage-free digital input
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-JB
- IOa, PLp, PLp, IOa 2 active current output HART 2 passive pulse output or status output
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-J
- R:SS trans+SS std-neck remote: stainless steel housing stainless steel terminal housing standard neck
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-H1
- Degreasing wetted surfaces Degreasing of wetted surfaces acc. ASTM G93/G93M-19, level C, test report
|
|
|
|
*
|
|
|
|
*
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-FF12
- FM XP tra+IS sen CDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP CDEFG)
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-FF11
- FM XP tra+IS sen ABCDEFG FM approval for USA and Canada explosionproof transmitter and intrinsic safe sensor (GP ABCDEFG)
|
|
|
|
*
|
|
|
|
*
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-E7
- L: 0,2% m flow+4 kg/m³ liquid: 0,2% mass flow accuracy and 4 kg/m³ density accuracy
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-E
- R:AL corr paint+ std-neck remote: low copper aluminium housing corrosion protection coating SS terminal housing standard neck
|
|
|
|
*
|
|
|
Yokogawa RCUH50S-D7
- L: 0,15% m flow+4 kg/m³ liquid: 0,15% mass flow accuracy and 4 kg/m³ density accuracy
|
|
|
|